iConverter 2-Module Power Chassis
Jellemzők
- 2-Module chassis feature an internal AC or DC power supply
- Houses all models of hot-swappable iConverter media converter and switch modules
- NEBS Level 3 Certification
- Ethernet backplane ports for connectivity to installed modules to support a wide variety of configurations
- Management is available with the addition of a management module to the chassis
- SNMP management via NetOutlook® provides real-time port and module information, remote parameter configuration and trap notification
- Optional support for wide temperature range of -40 to +60º C
- Wall-mount or tabletop options for flexible installations
- Lifetime Warranty and free 24/7 Technical Support
Alkalmazás
The iConverter 2-Module Power Chassis is a compact, versatile chassis featuring a single internal universal AC or 18-60VDC power supply. The chassis provides housing for all iConverter multi-service platform modules.
The 2-Module Chassis features a backplane that enables sharing of Ethernet data between two installed iConverter modules that are equipped with Ethernet backplane ports. This enables the chassis to support a variety of networking configurations. Installing an iConverter copper-to-fiber module and a four-port switch module provides a fiber uplink and five 10/100 user ports. A fiber-to-fiber module can be used to provide an access point in a fiber ring, supporting four 10/100 user ports.
In Enterprise networks, the 2-Module Chassis can be used to extend a fiber network connection across a campus or to add a node to an existing fiber ring. The 2-Module Chassis provides a carrier-grade solution; combining media conversion with a managed, compact edge switch.
In Service Provider networks, installing an iConverter Network Interface Device (NID) plug-in module and a four-port switch module provides a securely managed Carrier Ethernet demarcation for one or more User-to-Network Interfaces (UNI). This configuration provides an MEF certified deployment supporting advanced Operation, Administration and Maintenance (OAM) features.
Equipped with an iConverter management module or a module with integrated management, the 2-Module Chassis provides a securely managed solution capable of supporting advanced Ethernet services for Enterprise and Service Provider metro networks. It can be remotely managed via IP-based SNMP or Telnet.
Modules with integrated management, such as the iConverter 10/100M2, installed in the 2-Module Chassis can also provide remote management for the configuration and monitoring of the installed modules. This provides a flexible solution for Enterprise or Service Provider applications where a securely managed edge device is required.
The iConverter 2-Module Chassis can be wall-mounted using the optional wall mounting kit or installed on a stable, flat surface. It can also be rack mounted using the iConverter 19” rack-mount shelf.
Specifications
Chassis Type | 2-Module AC 8.5 watts |
2-Module AC 16.5 watts |
2-Module AC* High Airflow 16.5 watts |
2-Module DC 6.6 watts |
2-Module DC 16.5 watts |
2-Module DC* High Airflow 16.5 watts |
Model Number Standard Dying Gasp |
8230-0 8230-1 |
8231-0 8231-1 |
- 8232-1 |
8235-0 8235-1 |
8236-0 8236-1 |
- 8238-1 |
Module Capacity | 2 | |||||
Power Supply Capacity | Fixed Internal | |||||
Input Power Requirements (typical) | 100 to 240VAC, 50/60Hz 0.5A @ 120VAC 2.6A @ 3.3VDC 1.5A per slot |
100 to 240VAC, 50/60Hz 0.5A @ 120VAC 5A @ 3.3VDC 2.5A per slot |
100 to 240VAC, 50/60Hz 0.5A @ 120VAC 5A @ 3.3VDC 2.5A per slot |
+/- 18 to 60VDC -48VDC @ 1.0A 2A @ 3.3VDC 1.5A per slot |
+/- 18 to 60VDC -48VDC @ 2.0A 5A @ 3.3VDC 2.5A per slot |
+ / - 18 to 60VDC -48VDC @ 2.0A 5A @ 3.3VDC 2.5A per slot |
Dimensions | W:6.7" x D:5.51" x H:1.87" | |||||
Weight | 2.5 lbs | |||||
Compliance | UL, CE, FCC Class A, NEBS Level 3 | |||||
Temperature | Standard: 0 to 50º C Wide: -40 to 60º C Storage: -40 to 80º C |
|||||
Humidity | 5 to 95% (non-condensing) | |||||
Altitude | -100m to 4000m | |||||
MTBF (hrs) | 151,000 | 413,000 | 50,000 | 329,000 | 538,000 | 50,000 |
* Required for iConverter XG+ models. Register at Omnitron-Systems.com to download the iConverter XG+ Usage Guide.
Configuration | 2-Module AC 8.5 watts | 2-Module AC 16.5 watts | 2-Module AC High Airflow 16.5 watts | 2-Module DC 6.6 watts | 2-Module DC 16.5 watts | 2-Module DC High Airflow 16.5 watts |
---|---|---|---|---|---|---|
2-Module Chassis | 8230-0 | 8231-0 | - | 8235-0 | 8236-0 | - |
2-Module Chassis with Dying Gasp Support |
8230-1 | 8231-1 | 8232-1 | 8235-1 | 8236-1 | 8238-1 |
Wall-Mount Hardware Kit | 8249-0 | |||||
19" Rack-Mount Shelf | 8260-0 | |||||
Blank Module Panel | 8090-0 |
For wide temperature (-40 to 60º C), add a "W" to the end of the model number.
Consult factory for extended temperature (-40 to +75º C) models.