iConverter NMM2

Network Management Module

iConverter NMM2
Application Example

 

PDF_014_36x36.jpgadatlap

Jellemzők

  • Provides real-time management, trap notification and remote configuration
  • Supports SNMPv1, SNMPv2c, SNMPv3 and Telnet protocols
  • SNMP management via Omnitron’s NetOutlook® management software, or third-party SNMP management software
  • Password protected to prevent unauthorized access
  • Utilizes IEEE 802.3ah OAM extensions and Omnitron’s Secure OAM for IP-Less management
  • Managed via the front-plane RJ-45 Ethernet port, the front-plane serial port or the Ethernet interface of an adjacent module connected across the backplane
  • 10/100Mbps RJ-45 port supports auto or manual negotiation
  • LED displays for immediate visual status of each port
  • Hot-swappable in 19-Module, 5-Module, or 2-Module chassis
  • Lifetime Warranty and free 24/7 Technical Support

Alkalmazás

IP-less management requires an NMM2 in the core chassis, and a media converter with integrated management installed at each remote end of the IP-less managed link. In this application example, an iConverter 10/100M2 plug-in module is installed in the 19-Module chassis, and connected via the fiber link to a standalone 10/100M2 Network Interface Device (NID). This configuration enables the 19-Module master chassis to establish an IP-less management channel between the 10/100M2 link partners. The IP address resides only at the network core, and does not exist on the customer network.

The iConverter NMM2 provides comprehensive remote monitoring, configuration and alarm notification functions for all iConverter managed media converters and Network Interface Devices (NIDs). Installed in any slot of an iConverter chassis, the NMM2 manages all other modules and power supplies installed in the chassis through a high-speed management backplane. Additionally, all remote NIDs linked to the managed iConverter chassis may be managed by the installed NMM2 through a secure IP-less management channel.

Through the 10/100 RJ-45 Ethernet port, the NMM2 can be remotely accessed by IP-based management protocols, including SNMPv1/2c/3, TELNET and FTP. The serial console port provides local access and initial configuration from an RS-232 terminal. Management is accessed either via NetOutlook®, Omnitron’s SNMP Management Software, or by any third party SNMP management software. An intuitive Command Line Interface (CLI) can be accessed either via the serial port or TELNET.

The NMM2 provides real-time management, continuously collecting system status and module information. It reports the collected status to the network management applications and displays LED alarms for chassis power supplies. The NMM2 also provides comprehensive provisioning support for all local and remote iConverter modules, including port settings, VLANs and rate limiting. Network alarms are forwarded as traps to multiple trap hosts and recorded in a persistent system log.

In the event of a power outage, the NMM2 also supports dying gasp SNMP trap notification.

The NMM2 manages remote NIDs connected to the managed chassis via an IP-less management channel. Utilizing IEEE 802.3ah extensions, an NMM2 in a chassis at the network core can use a single IP address to manage up to 18 iConverter Network Interface Devices (NIDs) at different edge locations. This capability simplifies IP address management, improves network security and conserves the use of IP addresses.

Active Controls
  • Link Propagate/Link Segment
  • Remote Fault Detection
  • Module Name
  • Chassis Name and Number
  • IP Address
  • 802.3ah OAM Enable
  • Secure IP-less OAM Enable
  • Subnet Mask
  • Gateway
  • Management Port Disable
  • Alarm Threshold Setting
  • Software updates via FTP
  • Reset Chassis
  • Telnet
  • Trap IP's
  • FTP Enable
  • Password Selection
  • Soft Switch Reload
Module Information
  • Module Type
  • Slot Occupied
  • Part Number
  • Serial Number
  • Configuration
  • Revision
  • Ports on Module
  • User-defined Identifier
Module Status
  • Module Power
  • Link Status
  • Active Port
  • Diagnostic Status
  • Management
Alarms / Traps
  • Warm Start
  • Link Up/Down
  • Chassis Insertion/Removal
  • Authentication Failure
  • DIP-Switch Configuration Change
  • Software Configuration Change
  • Temperature Out-of-Range
  • Power Supply Out-of-Range
  • Power Supply Insertion/Removal
  • Chassis Reset
  • Module Reset
  • Module Insertion/Removal
  • Port Link State Change
  • Redundancy Primary Up/Down
  • Redundancy Secondary Up/Down
  • FTP Session Open/Close
  • Telnet Session Open/Close
  • Dying Gasp (Power Loss Trap)
Chassis Information
  • Part Number
  • Serial Number
  • Revision
  • Description
Chassis Status
  • Power Status
  • Power Output Voltage
  • Chassis Temperature

 

Paraméterek

Model Type iConverter NMM2
Protocols IP, UDP, SNMPv1, SNMPv2c, SNMPv3,
Telnet, TCP, FTP, ARP, ICMP, 802.3ah
Connectors RJ-45
Controls Pause Enable/Disable, Master/Slave,
Auto/Manual Negotiation, FDX/HDX, 10/100,
Backplane Enable/Disable
LED Displays Power, Power Supply (3), Master/Slave,
Mgt Poll, UTP 100 Link, UTP 10 Link, Duplex
Supported MIBs RFC1155, RFC1156, RFC1157,
RFC1212, RFC1213, OST MIB
Dimensions W:0.85" x D:4.5" x H:2.8"
Weight 8 oz.
Compliance UL, CE, FCC Class A, NEBS 3
Power Requirement 0.9A @ 3.3VDC (typical)
Temperature Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C
Humidity 5 to 95% (non-condensing)
Altitude -100m to 4000m
MTBF (hrs) 600,000
Model Description
8000N-0 iConverter NMM2 Module
8081-3 NMM2 Serial Cable (DB-9 Male to Female - 3ft.)
8082-0 NMM2 DIN-6 to DB-9 Female Adapter Cable
8100-0 NetOutlook SNMP Software