iConverter GXTM*

10/100/1000BASE-T UTP to 1000BASE-X Intelligent Media Converter and
Network Interface Device

iConverter GXTM
Metro Ethernet Access
Management System

 

PDF_014_36x36.jpgadatlap

*The iConverter GX/TM modules are not supported in future software releases and are not recommended for new designs or deployments. View the iConverter GX/TM2 web page.

Jellemzők

  • Carrier-Grade optical Ethernet Network Interface Device
  • Integrated SNMPv1, SNMPv2c, SNMPv3 and IP-less 802.3ah management
  • 802.3ah Link OAM for performance monitoring, early fault detection and dying-gasp
  • 802.1Q VLAN for E-Line and E-LAN services
  • Quality of Service for Voice/Data/Video over Ethernet
  • Port MIB statistics and optical performance statistics to support Service Level Agreements
  • Port Access Control for enhanced security
  • Configurable Link Fault Propagation modes
  • Small Form Pluggable (SFP) transceivers with Optical Statistics for standard or CWDM applications
  • Fixed-fiber connectors available for multimode and single-mode dual fiber and single-mode single-fiber
  • UTP auto-crossover and auto-negotiation of data rate, duplex modes and pause capabilities
  • Commercial (0 to 50ºC), wide (-40º to 60ºC) and extended (-40º to 75º C) temperature ranges
  • NEBS Compliant
  • Lifetime Warranty and free 24/7 Technical Support

Alkalmazás

The iConverter GX/TM conforms to the Ethernet in the First Mile (EFM) standards to support Fiber-to-the-X Metropolitan and Enterprise LAN networks. The GX/TM provides intelligent, securely managed service demarcation at the customer premises, offering Quality of Service capabilities. The GX/TM features built-in Operations, Administration and Maintenance (OAM) management with comprehensive monitoring, fault detection and provisioning.

The GX/TM is available as a compact standalone unit or as a chassis plug-in module. The hot-swappable GX/TM plug-in module can be mounted in a 19 or 5-Module chassis with any combination of redundant AC and DC power supplies. It can also be mounted in a 2-Module AC or DC powered chassis, or in a 1-Module chassis with AC or DC power input.

The plug-in module can manage other modules in the same chassis and operate as a managed 10/100/1000 media converter. It features two Ethernet backplane ports for connectivity to adjacent modules in a chassis for multi-port and multi-service configurations.

The standalone GX/TM is available as a tabletop or wall-mount unit. The tabletop model can be DIN-rail mounted using an optional DIN-rail mounting kit. Both the tabletop and the wall-mount models are DC powered and are available with an external AC/DC power adapter or a terminal connector for DC power. The GX/TM standalone unit combines management capability with a compact chassis for deployment at the demarcation point.

The iConverter family of managed fiber access media converters are used in Service Provider access networks and Enterprise LANs. iConverter media converters provide fiber connectivity with copper-to-fiber, multimode fiber to single-mode fiber, or dual fiber to single-fiber conversions.

 

Metro Ethernet Access

At the Central Office, the GX/TM plug-in module is installed in a managed iConverter 19-Module chassis for high-density fiber distribution from UTP switch equipment. At Customer Premises 1, the GX/TM plug-in module is installed in a 2-Module chassis with an iConverter 4TxVT four-port switch module. The two modules share data via the Ethernet Backplane. This configuration functions as a remotely managed demarcation switch with a fiber uplink port to the network core and four copper ports that drop off Ethernet service. At Customer Premises 2, the GX/TM standalone NID provides a fiber uplink to a single copper port for intelligent demarcation of Ethernet services.

Paraméterek

Description 10/100/1000BASE-T UTP to 1000BASE-X
Fiber Media Converter
and Network Interface Device
Protocols IEEE Std 802.3,
10BASE-T, 100BASE-TX, 1000BASE-T, 1000BASE-X with 1536 bytes max. frame size
UTP Cable EIA/TIA 568A/B, Category 5 and higher
Fiber Cables Multimode: 50/125, 62.5/125, 100/140μm
Single-mode: 9/125μm
Serial Cable RS-232, 22 to 24 AWG, 12 to 50 pF/ft.
UTP Connector RJ-45
Fiber Connectors
- SFP
- Dual Fiber
- Single-Fiber

LC
SC, ST, LC, MT-RJ
SC
Serial Connector Mini DIN-6 female,
mini DIN-6 male to DB-9 female adapter included
Controls DIP-Switches and LEDs
DC Power Plug-In Module: 1.5A @ 3.3VDC
Standalone: 8-15VDC,
0.6A @ 9VDC
DC Power Connector Plug-In: Power supplied by backplane
Standalone: 2.5mm Barrel Connector
or Field-wireable Terminal Connect
AC Power Adapter
[US]
Plug-In Module: N/A
Standalone: 100-120VAC/60Hz
0.08A @ 120VAC
AC Power Adapter [Universal] Plug-In Module: N/A
Standalone: 100-240VAC/50-60Hz
0.08A @ 120VAC
Dimensions Plug-In Module: W:0.85" x D:4.5" x H:2.8"
Standalone: W:3.1" x D:4.8" x H:1.0"
Wallmount: W:3.8" x D:4.8" x H:1.0"
Weight
without power adapter
Plug-In Module: 8oz.
Standalone: 1 lb.
Weight
with power adapter
Plug-In Module: N/A
Standalone: 1.5 lb.
Compliance and Specifications UL, CE, FCC Class A RFC 791, RFC 793, RFC 1122, RFC 2581, RFC 768, RFC 3410 - 3415, RFC 1213, RFC 1643, RFC 1650 Module is transparent to all protocols Layer 3 and above
IP-Based Management Telnet; SNMPv1, SNMPv2c, SNMPv3
Temperature Standard Operating: 0 to 50º C
Wide Operating: -40 to 60º C
Extended Operating: -40 to 75 º C
Storage: -40 to 80º C
Humidity 5 to 95% (non-condensing)
Altitude -100m to 4000m
MTBF (Hours) Plug-In Module and Standalone without Power
Adapter: 550,000
Standalone With Power Adapter: 250,000

GXTM_011_660x240.jpg

Fiber Type / Dual Fiber or Single-FiberDistancesConnector TypeTx λ (nm)Rx λ (nm)Min.
Tx Power (dBm)
Max.
Tx Power (dBm)
Min.
Rx Sense (dBm)
Max.
Rx Sense (dBm)
Link Budget
(dBm)
SCMT-RJLCSFP
SFP - - - - 8939-0 - - - - - - -
MM/DF 220/550m 8922-0 8924-0 8926-0 - 850 850 -10 -4 -17 -3 7
SM/DF 12km 8923-1 8925-1 8927-1 - 1310 1310 -9.5 -3 -19.5 -3 10
SM/DF 34km 8923-2 - 8927-2 - 1310 1310 -5 0 -23 -3* 18
SM/DF 80km 8923-3 - 8927-3 - 1550 1550 -5 0 -23 -3* 18
SM/DF 110km 8923-4 - 8927-4 - 1550 1550 0 5 -24 -3** 24
SM/DF 140km 8923-5 - 8927-5 - 1550 1550 2 5 -28 -8*** 30
SM/SF 20km 8930-1 - - - 1310 1550 -9.5 -3 -20 -3 10.5
SM/SF 40km 8930-2 - - - 1310 1550 -3 0 -20 -3* 17
SM/SF 20km 8931-1 - - - 1550 1310 -9.5 0 -20 -3* 10.5
SM/SF 40km 8931-2 - - - 1550 1310 -3 0 -20 -3* 17
SM/SF 20km 8932-1 - - - 1310 1490 -9.5 -3 -20 -3 10.5
SM/SF 20km 8933-1 - - - 1490 1310 -9.5 -3 -20 -3 10.5

 
When using single-fiber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other.
*A minimum of 3dB of attenuation is required for these models.
**A minimum of 8dB of attenuation is required for this model.
***A minimum of 13dB of attenuation is required for this model.
When ordering a Wide Temperature model, add a "W" to the end of the part number, and when ordering an Extended Temperature model, add a "Z" to the end of the part number (see chart above).

Chassis and Mounting Options Ordering Table

 19-Module5-Module2-Module1-Module
ConfigurationAC
(60 watts)
AC
(120 watts)
24VDC48VDCAC24VDC48VDCAC18-60DCUS ACUNIV AC
One (1) Power Supply 8200-1 8201-1 8206-1 8205-1 8220-1 8226-1 8225-1 8230-0 8235-0 8240-1 8240-2
One (1) Power Supply with Dying Gasp Support - - - - - - - 8230-1 8235-1 8241-1 8241-2
Two (2) Power Supplies 8200-2 8201-2 8206-2 8205-2 8220-2 8226-2 8225-2 - - 8245-111* 8245-112*
Three (3) Power Supplies 8200-3 8201-3 8206-3 8205-3 - - - - - - -
Spare Power Supply 8200-9 8201-9 8206-9 8205-9 8220-9 8226-9 8225-9 - - - -
23" Rack Mounting Kit 8091-2 8091-2 8091-2 8091-2 8092-2 8092-2 8092-2 - - - -
Blank Module Panel 8090-0 8090-0 8090-0 8090-0 8090-0 8090-0 8090-0 8090-0 8090-0 - -
Wall Mounting Hardware Kit -   - - - - - 8249-0 8249-0 8249-0 8249-0
1U 19" Rack Mount Shelf - - - - - - - 8260-0 8260-0 8260-0 8260-0
DIN Rail Mounting Kit -   - - - - - - - 8250-0 8250-0

 
When ordering a Wide Temperature chassis, add a W to the end of the part number. For example:8230-1W
Consult factory for extended temperature (-40 to +75º C) models.
* Click on part number for complete ordering information on the 1-Slot Redundant Power Chassis with Power over Ethernet